TP3032
TP3032 series high voltage power supply is a high voltage pulse power supply, the output pulse voltage can reach 10kV. The output pulse voltage is continuously adjustable through another high-voltage power supply, the frequency of the output pulse is fixed at 100Hz, and the frequency and pulse width of the output pulse can be displayed on the digital LCD screen. In addition, this power supply also has various protection functions, which makes the performance of the power supply more stable and can well meet the needs of users.
Typical Application:medical application
Back to list
Features
- Output pulse voltage 10kV
- the output pulse voltage is continuously adjustable
- output pulse current 100A
- output maximum pulse power 1000kW
- with voltage
- frequency
- pulse width display
- with overvoltage and overcurrent protection and other functions
- can be customized according to user requirements
CONTACT US
Telephone:+86411-84754722
Mobile:+8615642371743
Wechat:15642371743
Email:chengxingqi@teslamanhv.com
URL:www.teslamanhv.com
Product Specifications
Input voltage
220VAC, 50Hz.
Output voltage
DC10000V±0.1%V, continuously adjustable from 0 to the highest voltage.
Output pulse current
200A.
Output pulse width
10~100uS.
Time drift accuracy
0.01% every 8 hours after 30 minutes.
Temperature drift accuracy
0.01% per degree Celsius.
Output adjustment and display
The LCD screen on the front panel of the power supply can display the output status, frequency and pulse width and other information, and the voltage value can be adjusted through the voltage adjustment potentiometer, and the pulse width can also be set through the buttons on the panel.
Voltage Control Power Panel
The multi-turn potentiometer that comes with the power panel can set the output voltage between 0V and the highest voltage.
Voltage control External remote control
An external 0 to 10V control signal can adjust the output from 0V to the highest output voltage.
Voltage regulation Relative load
0.01% (no load to rated load).
Voltage regulation Relative input
±0.01% (input voltage change is ±10%).
Current regulation relative load
0.01% (no load to rated load).
Current regulation Relative input
±0.01% (input voltage change ±10%).
Ambient temperature
-10℃ to +50℃ when working. Storage -20°C to +80°C.
Voltage and current indication
0 to +10V, 1% accuracy under rated output conditions.
Dimensions
width 482.6mm, height 355.6mm, depth 865mm.
Pulse output connector, high-voltage input connector
A recessed epoxy resin insulating conduit and a probing high-voltage cable are connected through a metal connector with a diameter of 16mm (high-voltage input on the pulse power supply is provided by another DC high-voltage power supply).
High-voltage cable
The high-voltage power supply provides a high-voltage shielded cable with a standard length of 1 meter (the cable length is optional) to connect the high-voltage power supply and the load.