TXF1200 X-Ray HV Power Supply

TXF1200

TXF1200 series is specially designed for X-ray tubes with negative high- voltage anode grounding float filament. Input +24VDC, output high voltage of 1kV~70kV, up to 2mA emission current, maximum power 100W. TXF1200's emission current is controlled by a closed loop to ensure the high stability of the emission current. Floating filament power supply works at 0.3A to ~5A. TXF1200 has the characteristics of adjustment accuracy, high stability, low ripple, small size, etc., and provides users with local and remote analog control voltage, emission current and filament current limit settings. USB2.0, RS232, RS485, network port digital interface is available.

Typical Application:Global brands of X-ray tubes, thickness gauges, X-ray fluorescence meters, X-ray diffraction meters, X-ray imaging, sulfur meters, non-destructive detection, portable X-ray machines, online element analysis, X-ray perspective, particle size detection, density measurement, paper composition detection, ROHS detectors, precious metal detectors, plastic sorting, Crystal detection, electroplating measurement, mineral analysis, wavelength dispersion spectrometer, life science, medical chemical industry, scientific experiments, industrial applications.

 

Reference Back to list

Features

  • Optional RS232 RS485 network port control
  • 70kV 2mA up to 100W
  • Integrated suspended filament power supply
  • Overvoltage and output short circuit protection arc protection
  • Voltage and current regulation function
  • Local or remote control
  • Security interlock function
  • It can be customized according to user requirements.

CONTACT US

Address:16 Renxian Street, High-tech Industrial Zone, Dalian, China
Telephone:+86411-84754722
Mobile:+8615642371743
Wechat:15642371743
Email:chengxingqi@teslamanhv.com
URL:www.teslamanhv.com
DaLian Teslaman XingQiCheng

Product Specifications


Input

+24VDC±10%, the maximum current at 70W output is 5A, and the maximum current at 100W output is 8A.

Output

A variety of maximum voltage outputs from 0 to 70kV are available.

Stability

After warm-up for half hour, it is less than 0.02% every 8 hours.

Temperature coefficient

Voltage and current are better than 25ppm/℃.

Ripple

Under rated output conditions, it is better than 0.1% p-p.

Voltage and current display

0~+10VDCMatch0~100%Rated output,Zout=10kΩ, accuracy ±1%.

Internal control of output voltage

The internal potentiometer sets the voltage to 0~100% rated output.

External control of output voltage

Outside0~+10VDCThe control signal can set the voltage in0~100%Rated output,Zin=10MΩ.

Internal control of output current

The internal potentiometer sets the current to 0~100% rated output.

External control of output current

Outside0~+10VDCThe control signal can set the current at0~100%Rated output,Zin=10MΩ.

Voltage relative load adjustment rate

0.01% (no load to rated load).

Voltage relative input adjustment rate

±0.01% (input voltage change±10%).

Current relative load adjustment rate

0.01% (no load to rated load).

Current relative input adjustment rate

±0.01% (input voltage change±10%).

Filament power supply

Constant current output, the output current adjustment range is0.3A to 5A, output voltage limit is 5V.

Ambient temperature

When working 0℃~+50℃. Storage -40℃~+85℃.

Humidity

20%~85%. Relative humidity, no condensation.

External dimensions

10 to 50kV

75mm wide, 185mm high and 205mm deep.

51 to 70kV

75mm wide, 185mm high and 228mm deep.

Weight

About 5kg.

Download