TXP1310 X-Ray HV Power Supply

TXP1310

Teslaman’s TXP1310 redefines the standard for high performance, low cost Mammography X-Ray generators. TXP1310 X-Ray generator integrates a dual filament power supply and a dual speed starter. A DC current source filament power supply provides fast rise times with stable and accurate X-Ray tube emission currents. The solid encapsulated high voltage output section eliminates oil concerns while reducing the effects of environmental humidity and contamination. Flexibility in interfacing is provided via RS-232 and optional Ethernet connectivity. The VMX supports advanced mammography application features including Smart AEC Exposure, Automatic Filament Calibration, Tube Anode Heat Calculator and user configurable Tube Library. Compact, full featured, high performance, low cost. TXR1310, the next generation Mammography X-Ray generator.

Typical Application:Mammography

 

Reference Back to list

Features

  • Custom Designed Specifically for Mammography Applications
  • Fast Settling Helps Minimize Patient Radiation Exposure
  • Dual Speed Starter Boost/Brake Capability
  • RS-232 and optional Ethernet interface
  • Low-cost and value-added design

CONTACT US

Address:16 Renxian Street, High-tech Industrial Zone, Dalian, China
Telephone:+86411-84754722
Mobile:+8615642371743
Wechat:15642371743
Email:chengxingqi@teslamanhv.com
URL:www.teslamanhv.com
DaLian Teslaman XingQiCheng

Product Specifications


Input voltage

220VAC ±10%, single phase, 50Hz/60Hz.

Input current

Minimum 35A service recommended for 5kW operation

Output voltage range

20kV to 40kV

Polarity

Positive, grounded cathode X-Ray tube

Accuracy

Within 1% of programmed values

Repeatability

<0.5%.

Stable time

<10ms.

Ripple

≤ 1%

Stability

≤ 0.01% per 8 hours

Temperature Coefficient

100ppm/℃.

Output current range

10mA to 200mA.

Output power

5kW@0.1 second loading time

Maximum mAs

600mAs

Exposure timer

5ms-10Small size.

Accuracy

Within 2% of programmed values measured after mA rises to stable DC level

Repeatability

<0.5%.

Stable time

<10ms.

Filament configuration

DC filament drive

self corrected filament preheat settings with closed loop emission control and smart learning algorithm.

Filament output

0-6A, 5.5V, maximum.

Dual Speed Starter

High speed (180Hz) and low speed (60Hz) can be configured via the serial interface. Boost and Brake capability provided.

High-voltage connector

60kV, Clayrmont CA-3 type or equivalent

Optional communication interface

RS232、Ethernet (RJ45).

Grounding Point

M5 grounding stud provided on chassis.

Environmental

Operating 10̊to 40̊ Storage -40̊to 85̊

Humidity

20% to 85% RH, non-condensation.

Cooling

Convection cooled, no internal fan. Forced air cooling not requied.

Dimensions

Width 169.9mm, height 240.8Mm, depth 304.8mm.

Weight

About 10kg

Download