![TXF1272 X-Ray HV Power Supply](/uploadfile/2025/0212/20250212011713632.png)
TXF1272
Teslaman TXF1272 series X-ray high voltage power supply is a compact power supply with negative, positive, or bipolar output options, with a power of 6.0 kW, and an output voltage range of 160 kV to 450 kV, suitable for various application needs. The power supply adopts an active power factor correction circuit, with a high power factor and low input current, and reduces line-related electromagnetic interference to a minimum. TXF1272 adopts a proprietary inverter topology technology to make the power supply more efficient and higher in power density. The high-voltage part of the power supply is packaged in a solid-state way to reduce volume and weight and improve the reliability and maintenance convenience of the product. The power supply uses DSP technology based on SMT control circuits and provides various interfaces such as USB, RS-232, Ethernet, and analog signals to facilitate integration into OEM systems. The power supply has two DC outputs, and the stable emission current regulation circuit controls the filaments power supply, providing precise and stable current to the X-ray tube. In addition, the power supply also has a comprehensive fault diagnosis circuit, arc monitoring, arc extinguishing, and arc counting functions.
Typical Application:Non-destructive testing,X-ray scanning,Secure applications,Medical applications,Al Visual Recognition
Reference Back to list
Features
- 160kV 225kV 320kV and 450kV Mode
- 6kW
- Build in PFC circuit
- Integrated double filament power supply
- Solid encapsulation
- USB Ethernet and RS232 ports
CONTACT US
Telephone:+86411-84754722
Mobile:+8615642371743
Wechat:15642371743
Email:chengxingqi@teslamanhv.com
URL:www.teslamanhv.com
![DaLian Teslaman XingQiCheng](/statics/en/images/wx_cxq.png)
Product Specifications
Input Voltage
208 or 400VAC±10%, three phase, 47-63 Hertz, passive power factor corrected
Input Current
<25 amps per phase for 208VAC. <15 amps per phase for 400VAC.
Output Voltage
Accuracy
0.25%
Stability
≤ 0.1% per 8 hours, after 1 hour warm up
Load
±0.1% of rated output voltage for a full load change
Line
±0.1% of rated output voltage over specified input voltage range
Temperature Coefficient
50ppm/°C
Emission Current
Temperature coefficient
100ppm/°C
Load
±0.1% of rated output current for a change from 30% to 100% of rated output voltage
Line
±0.1% of rated output current over specified input voltage range
Filament
Output
0-6 amps at a compliance of 10Vdc, maximum
Dual Focal Spot
Small and large, selectable via interface signal
Configuration
DC filament drive. Closed loop emission control regulates filament setting to provide desired X-Ray tube emission current
Polarity
Specify negative or positive when ordering
Environment
Work
0°C To +50°C.
Storage
-40°C To +85°C.
Mains Input Connector
MS3106A24-11S
Interface Connector
Digital—Ethernet, RS-232 and USB Analog—25 pin connector
Cooling
Forced air