TXMP1006 X-Ray HV Power Supply

TXMP1006

Teslaman TXMP1006 is a modular 10kV @ 10W X-Ray generator designed to drive a grounded filament X-Ray tube via closed loop filamentary control of the 0 to 1mA emission current. The grounded filament supply is rated at 0-5 amps @ 3Vdc. The filament supply features an internally adjustable 0.5 to 2.5 amp filament preheat and a internally adjustable 0 to 5 amp filament limit.

Typical Application:RoHS analyzer, fluorescence analysis, liquid level detection, film/metal thickness measurement, PCB board inspection, other imaging and X-ray inspection occasions, AI recognition, can be adapted to various cathode grounded X-ray tube

Reference Back to list

Features

  • RS-232、RS-485 interface
  • High stability,low ripple,low noice
  • Integrated ground referenced filament supply
  • Voltage and current control
  • OV,Arc and short-circuit protection
  • Local and remote programming
  • OEM customization available

CONTACT US

Address:16 Renxian Street, High-tech Industrial Zone, Dalian, China
Telephone:+86411-84754722
Mobile:+8615642371743
Wechat:15642371743
Email:chengxingqi@teslamanhv.com
URL:www.teslamanhv.com
DaLian Teslaman XingQiCheng

Product Specifications


Input

DC24V±10%, 2 amp maximum。

Output

Rated voltage of 10kV,20kV,30kV.

Stability

Less than 0.007%/hour, less than 0.02%/8 hour, after 0.5 hour warm-up.

Temperature Coefficient

<25ppm/℃.

Ripple

Less than 0.005%p-p under rated output condition.

Voltage Accuracy

<2%

Emission Current

0-1mA

Current Accuracy

<1% (above 10% of maximum output current)

Current Stability

< 0.02%

Filament Output

A captive 500mm long unterminated 16 AWG twisted wire pair is provided.

Voltage Regulation

Line

<0.01% for input voltage change of ±10%

Load

<0.01% for zero to full load

Current Regulation

Line

≤0.01% for 10% input voltage change under any load conditions

Load

≤0.01% for full load to short circuit

Filament Supply

Voltage

0V to 3Vdc referenced to ground

Load Current

5A max, preset adjustable limit

Stability

< 0.25% per 8 hours at constant operating conditions

Ripple

<50mV p-p (at maximum load current). Temperature Coefficient

Environmental

Operating

5˚C to 40˚C

Storage

-40˚C to 70˚C

Humidity

Operating

20% to 80% RH, non-condensing

Storage

5% to 95%

Dimensions

0kV to 10kV

W70mm,H30mm,D160mm。

20kV to 30kV

W70mm,H30mm,D200mm。

Download