TXB1810 X-Ray HV Power Supply

TXB1810

TXB1810 Series of X-rays High-Voltage power supply rated output voltage is 80kV and the power is 100W.Built-in ray tube. Product Small size, with Standard analog interface and RS-232 digital interface and other features can be easy integrated into your X-ray system. The proprietary emission control circuit provides excellent X-ray tube current management and excellent stable performance.

Typical Application:Thickness measurement, food inspection, liquid level detection,package inspection X-ray scanning - bone density measurement

 

Reference Back to list

Features

  • Integrated high-voltage power supply
  • filament power supply
  • X-ray tube
  • beam port and electronic controller in one
  • Compact model and light weight
  • Universal input
  • correcting the power factor through the internal EMI filter
  • It can be installed in any physical position.
  • Analog control interface and standard RS-232 digital interface

CONTACT US

Address:16 Renxian Street, High-tech Industrial Zone, Dalian, China
Telephone:+86411-84754722
Mobile:+8615642371743
Wechat:15642371743
Email:chengxingqi@teslamanhv.com
URL:www.teslamanhv.com
DaLian Teslaman XingQiCheng

Product Specifications


Input voltage

The power factor correction input is 0.98, 100-240Vac±10%, 50-60Hz,maximum 2A.

X-ray tube voltage

X-ray tube voltage adjustable,1kV Up to 80kV.

X-ray tube current

Within the specified ray tube voltage range, the current of the ray tube is from 150 μA to 1.25 mA Adjustable.

X-ray tube power

Maximum continuous power 100W。

Voltage regulation

Input

When the specified input voltage of ±10% changes, the change of the maximum output voltage is ±0.05%.

Load

Electric current from 150 μA to 1.25mA changes, the voltage changes by ±0.1% of the maximum rated voltage.

Voltage accuracy

The error of the voltage measured by the X-ray tube is ±2%.

Voltage rise time

Standard

The maximum rated output voltage is from 10% to 90%, and the rise time should be 500 ms Optional 5 seconds.

Ripple

Under the rated output condition, it is better than 1% p-p (0.1% p-p optional).

Current regulation

Input

When the rated input voltage of ±10% changes, the change of the rated output current is ±0.05%.

Load

When the rated output voltage changes from 50% to 100%, the rated output current changes by ±0.1%.

Current accuracy

The error of the current measured by the X-ray tube,Better than±2%.

Current rise time

Standard

When the maximum rated current changes from 10% to 90%,the rise time less than 500ms。

Optional.

5 seconds.

Analog interface

The ground reference 0 to 9VDC is used for all programming signals and monitoring signals. Relay contacts and collector open signals are used as other signals. See the analog interface connector pin table.

Digital interface

To enable the RS232 interface, you need to configure the jumper and install the digital interface cable control software.。

Ambient temperature

Operational 0℃Up to +40℃.

Storage

-40℃Up to +70℃。

Humidity

The relative humidity is 10% to 95%, and there is no condensation.

Cooling

Forced air and natural convection augmented by customer provided external cooling fan to maintain oil temperature below 55°C.Analog interface connector

Digital interface connector

9-pin D-type connector, female.

Ground

8-32 grounding studs are available on the chassis.

Dimensions

See figures

Weight

14.5Kg.

Download