Performance of a 160 kV High Voltage Power Supply in Signal Amplification and Gain Uniformity of Microchannel Plate Detectors

A microchannel plate detector turns a handful of photoelectrons into a charge cloud large enough for the readout electronics, and the multiplication is set by the bias across the plate. At one hundred and sixty kilovolts the assembly is usually a stack of plates with a photocathode at the top and a phosphor or an anode at the bottom, and the supply has to hold a voltage that few other instruments demand.

The gain of a channel is not linear in voltage. A small change of bias produces a much larger change of output charge, because the multiplication follows an exponential relationship along the channel wall. Numbers quoted in the literature vary with plate geometry, but a working rule for field work is that a tenth of a percent of voltage error lands in the one to two percent range of gain error. That ratio is the reason a detector supply is specified in parts per million rather than in percent.
Uniformity across the plate is a different quantity from stability in time. Two plates from the same batch can differ by several percent in mean gain, and within one plate the gain falls towards the edge where the channel length and the wall coating are less ideal. The supply cannot correct a physical gradient inside the plate, but the supply can avoid adding a second gradient on top of the first.
The second gradient usually comes from the grading chain. A resistive divider that sets the inter-plate voltages has to hold a fixed ratio from the photocathode down to the anode, and the ratio is disturbed by surface leakage on the divider body, by leakage through the potting, and by any path from an intermediate node to ground. A leakage of a few nanoamperes at one node of a high megohm chain shifts that node by kilovolts, and the shift appears as a band of lower gain across one half of the field of view.
Field data from a returned assembly illustrates the scale. A plate that had passed acceptance with a flat field of two percent showed a six percent gradient after eight months in a humid room. The divider had been potted but the potting had a void near the top resistor, and the surface path carried about twelve nanoamperes in the damp season. Replacing the divider restored the flat field, and the supply had not moved by more than forty parts per million over the same period.
Ripple and noise act on gain in a way that is easy to underestimate. Any voltage fluctuation on the bias modulates the multiplication, and the modulation is synchronous with the readout if the fluctuation comes from the readout clock or from a common supply rail. The result is fixed pattern noise that looks like a detector artefact and cannot be removed by flat field correction, because the pattern moves with the operating point.
The practical threshold is set by the readout. A twelve bit readout with a full well of a few million electrons has a least significant bit that corresponds to a fraction of a percent of signal. Voltage noise at the level of ten parts per million produces gain noise below that bit, and a supply that reaches that level in the band from direct current to a few hundred kilohertz is adequate for most imaging work. Above that level the noise becomes visible in a flat field.
Load behaviour matters more than the static specification suggests. The charge delivered by a plate during a single event is small, but the event rate can be high, and the average current drawn from the supply is the product of charge per event and event rate. At high rates the supply sees a current step, and the response of the loop to that step determines whether the gain sags during a burst of events.
A supply that regulates through a long cable needs the cable capacitance in the loop model. The capacitance of a metre of high voltage cable is small in absolute terms and large compared with the charge per event, so the loop can hold the terminal voltage while the plate voltage lags. The lag is not visible on a meter and is visible on a fast flat field measurement taken during a burst.
Protection design runs against the same physics. An arc in the plate assembly dumps the stored energy of the cable into a small area, and the damage is proportional to the energy rather than to the current. A current threshold set for steady operation will not limit the arc energy, because the arc current rises faster than the threshold can respond. A rate of change detector, set between the normal charging current and the arc current, interrupts the discharge before the energy reaches the damaging level.
The judgement on how much protection is needed comes from the cost of the plate. A stack of large format plates is the most expensive single item in the detector, and a supply that saves a few hundred euros on protection can destroy a plate worth many times that amount in one event. The trade is not close, and the field record supports the conservative choice.
Calibration of gain uniformity is usually done with a uniform illumination source and a reference plate. The procedure that works in practice separates the plate response from the supply response: the illumination is kept identical, the bias is stepped over a small range, and the change of output is compared with the expected exponential slope. A supply whose slope deviates from the expected value has a measurement problem in the divider, not a gain problem in the plate.
Temperature is a slow variable that behaves like a fast one at high voltage. A divider with a temperature coefficient of fifty parts per million per degree moves by a few hundred parts per million over a working day in a room without control. The gain moves with the divider. A divider that is thermally bonded to a metal block, with the block held a few degrees above ambient, keeps the drift inside the calibration interval.
Cable routing decides how much of the room reaches the detector. A high voltage cable that runs beside a pump cable picks up the pump's switching transients, and the transients appear as gain modulation at the pump frequency. Twisting the pair, or separating the two cables by a hand's width, removes most of the coupling. The measurement that reveals the coupling is a flat field taken with the pump running and again with the pump stopped.
Connectors are the least reliable part of the high voltage path and the most often overlooked. A connector that has been mated and unmated a few dozen times develops a contact resistance in the milliohm range at the low current end of the chain, and the resistance is in series with a divider leg of megohms, which sounds harmless. The harm comes from the variation, not the value: a contact that changes by a few milliohms with temperature produces a gain step that repeats with the thermal cycle.
Commissioning an assembly of this kind ends with a set of numbers that belong to the installation rather than to the supply. Flat field uniformity at three bias points, drift over four hours, noise in the readout band, and response to a known charge step. A supply that meets the datasheet and fails one of those four numbers is a supply that will be blamed for a detector problem later.
The uniformity figure quoted on a datasheet is a mean over the plate, and the mean hides the pattern that matters. A plate with two percent mean non uniformity can have a four percent local difference between the centre and a corner, and the corner is where the calibration source usually saturates first. Flat field data taken at a bias slightly below the operating point shows the pattern without saturation, and the same bias point is a useful reference for every later comparison.
Bias polarity changes the calibration without changing the supply. Reversing the stack for a different photocathode design reverses the direction of the grading chain, and a divider that was trimmed for one direction shows a different distribution in the other. The trim procedure has to be repeated after a polarity change, and the record should note which direction was trimmed and when.
Service planning benefits from a small amount of forethought. A supply that reports the divider node voltages through an isolated measurement chain allows a service visit to start with a comparison rather than with a disassembly. The measurement chain costs a few resistors and an isolation amplifier, and the saving is a technician's afternoon per visit.
What happens after an event is as important as the event. A protection that trips and waits for a manual reset costs an hour of imaging, and a protection that re-arms after a defined interval costs a minute but requires that the re-arm be counted and reported, so the operator can decide whether the plate has been damaged.
A gain map recorded at one set voltage says nothing about the map at another. Slope is the number worth carrying into the field.