Precise Synchronization of Pulse Repetition Frequency of Excimer Laser Source High Voltage Power Supplies in Lithography Process

An excimer source fires several thousand times a second, and each pulse has to arrive at the scanner's slit at the moment the stage is in position and with an energy inside a narrow window. The supply's job is to deliver a defined charge to the discharge electrodes at a defined time, and both the charge and the time are parts of the dose specification.

The discharge is a fast event with a negative resistance, and the pulse power stage is usually a magnetic pulse compression chain fed by a capacitor bank. The bank is charged by a resonant converter between pulses, and the charging has to complete before the next trigger with a margin that absorbs the variation in the load. A charging time that is too close to the pulse interval produces a first pulse of a burst that is weaker than the rest.
Repetition rate stability is a timing specification before an energy specification. A jitter of a few nanoseconds between the trigger command and the actual discharge shifts the pulse in the scanner's scan window, and the shift shows up as a dose error even when the pulse energy is correct. The supply's trigger path, from the controller to the switch, has to be short, shielded, and defined in delay.
Energy control is a closed loop around a measurement that arrives once per pulse. The pulse energy is measured by a photodiode or an energy sensor, and the measurement arrives after the pulse has already happened. The correction is therefore applied to the next pulse, and the loop's bandwidth is limited by the repetition rate. At a few kilohertz the loop can correct slowly varying drifts and cannot correct pulse to pulse noise.
Pulse to pulse stability depends on the gas state as much as on the electrical design. The gas mixture changes with each discharge, halogen depletion reduces the gain, and the acoustic wave from one pulse perturbs the next if the interval is short enough. The supply sees these changes as a varying load, and a charging scheme that adapts to the measured energy rather than to a fixed charge time follows the gas state without extra sensors.
Burst operation is where the dose specification is hardest. A burst of a few hundred pulses has a first pulse that differs from the steady pulses, because the gas and the electrodes are in a different state after a pause. A first pulse energy control, which charges the first pulse to a different setpoint and blends into the steady setpoint over the first few pulses, is what keeps the burst dose inside the window.
Timing distribution across the machine is a cabling problem. The trigger signal travels to the supply, the energy measurement travels back, and the scanner's synchronization signal travels in parallel with both. Cable lengths that differ by a few tens of centimetres introduce delays that differ by a nanosecond or so, and at these rates a nanosecond is a measurable fraction of the acceptable window.
Electromagnetic interference from the discharge is severe and close to the control electronics. The discharge current rises in tens of nanoseconds and the loop area of the electrode circuit radiates into the trigger and measurement paths. Shielded twisted pairs with a single point ground, and a trigger receiver with a defined threshold and hysteresis, prevent the interference from being counted as a pulse.
Capacitor bank lifetime is expressed in pulses, and the number is large. A bank that is specified for a few billion pulses at a defined charge voltage is the normal case for this application, and capacitance falls with age. A charging scheme that measures the charge time and compares the time with a reference detects the loss of capacitance before the pulse energy falls out of specification.
Electrode erosion changes the discharge impedance over the life of the chamber. The supply's pulse forming network is matched to a new set of electrodes, and the match drifts as the electrodes wear. The visible effect is a reflected energy that heats the network instead of the gas, and the compensation is a change of the charging voltage that the controller applies as the pulse count accumulates.
Maintenance intervals are set by pulse count rather than by calendar time, and the counters have to be trustworthy. A counter that misses pulses because a trigger was rejected undercounts the wear, and the chamber is serviced late. Counters that increment on the measured energy rather than on the command are more accurate and in a machine that runs continuously such counters are the only ones worth keeping.
Commissioning a source supply includes a measurement of the delay from the trigger command to the optical pulse, taken over many pulses and reported as a distribution rather than a mean. The distribution's width is the jitter that the scanner has to tolerate, and a mean without the width tells the integration engineer nothing useful.
The optical measurement chain has a delay that belongs in the timing budget. The energy sensor, the sampling circuit, and the digital filter together add a latency of several pulses, and the correction loop is therefore acting on information that is a few hundred microseconds old. A loop gain that is correct for a slow drift becomes unstable when the gas state changes quickly, and the instability appears as a growing oscillation in pulse energy.
Pulse counting and dose accumulation must be independent of the controller's task load. A counter that increments in a background task misses pulses when the processor is busy, and the controller is busiest during a scan, which is exactly when the count matters. A hardware counter that increments on the trigger input, read by the controller at intervals, removes the dependency.
Gas replenishment is a slow control loop that interacts with the fast energy loop. A replenishment that adds halogen after a burst of pulses changes the gain of the next burst, and the energy loop compensates within the first pulses, which is acceptable. A replenishment that runs during a burst changes the gain within the burst, and the dose of that burst is outside the window. Sequencing the replenishment between bursts is a scheduling decision with a measurable effect.
One failure mode deserves attention because the symptom is misleading. A trigger receiver that is picking up interference from the discharge counts spurious triggers, and the supply fires more pulses than the scanner expects. The dose per scan rises while the per pulse energy looks normal, and the fault is initially attributed to the scanner's metering. A receiver with a defined minimum pulse width and a defined dead time rejects the interference without rejecting real triggers.
Chamber window contamination attenuates the optical path, and the energy loop compensates by raising the charging voltage. The compensation hides the contamination until the loop runs out of range, and then the energy falls abruptly. A comparison between the charging voltage and a reference curve over pulse count shows the contamination trend before the limit is reached, and the window can be cleaned on a planned basis.
Timing accuracy degrades gracefully rather than failing outright when a cable or a connector ages. A connector with a rising contact resistance slows the trigger edge, and the delay grows by a fraction of a nanosecond per month. The distribution of the delay widens before the mean moves, and a monthly measurement of the distribution catches the aging while the machine is still inside specification.
Commissioning the source should end with a burst test at the highest repetition rate the machine will use in production, not at a comfortable rate. The thermal and gas behaviour at the highest rate is what the dose specification has to hold, and a machine validated at a lower rate will pass the acceptance test and fail in the first production week.
The charging converter's switching frequency is chosen partly to keep the ripple out of the energy measurement band. Ripple on the charging voltage becomes a pulse to pulse energy variation, and the variation is visible in the dose even when the average is correct. Moving the switching frequency above the measurement bandwidth, or synchronizing the switching to the pulse clock, reduces the coupling at a cost of a larger filter.
The trigger path's shielding is not only about interference into the trigger. The trigger line also radiates, and a fast edge on an unshielded line couples into the energy measurement and into the scanner's synchronization input. A coaxial trigger path with a defined source impedance is the arrangement that keeps both directions quiet, and the cost is a connector rather than a redesign.
Gas pressure and composition are measured by the source controller, and the supply only sees the consequences. A record that puts the charging voltage, the pulse energy, and the gas state on the same time axis makes the interactions visible; separate records leave the interactions invisible and leave the discussion at the level of symptoms.
A source that has been in service for years tells the truth about timing in the records rather than in the specifications.
A late pulse is a missed pulse. Late by a nanosecond is still late.