
TEL4520
TEL4520 high voltage direct current power supply is a high-performance equipment with an output power of up to 33 kW adopting modular design and featuring excellent scalability and reliability. With an input voltage of 380 VAC and an output voltage of up to 3 kV, it has high precision control and high energy conversion efficiency, and is equipped with an efficient liquid cooling heat dissipation system to ensure stable operation for a long time. The device supports a charge and discharge repetition of 0.1 - 600 Hz, and has remote control function, allowing users to achieve precise regulation and real-time monitoring of output parameters through external interfaces. a high-power capacitor charging and discharging power supply, TEL450 is particularly suitable for excimer laser systems with strict requirements on power stability and response speed, and an ideal solution for industrial laser applications.
Typical Application:Laser power supply, capacitor charging and discharging.
Reference Back to listFeatures
- efficiency>85%
- 33kW output power
- Missing phase protection
- Charging repeat precision±0.1%
- Parallel available
- Auto inhibit function
CONTACT US
Telephone:+86411-84754722
Mobile:+8615642371743
Wechat:15642371743
Email:chengxingqi@teslamanhv.com
URL:www.teslamanhv.com

Product Specifications
Input
380VAC (342 - 418VAC) 3Phase, 49.8-50.2 Hz. Power supply will recover from voltage dips and sags according to IEC 61000-4-11 (Grade one, the voltage drops to 70% of the rated voltage). Inrush current <= maximum operating current, Ground Leakage current <= 5 mA. Separate M6 ground stud (metric size) on the rear panel.
Output
0kV to 3kV. Output voltage overshoot smaller 0.1% of full scale 3kV, measured at the 5 meter-long cable end output.
Output power
About at 100 % of rated voltage (charge 21µF in 1ms from 0V to 3000V), exact value determined by critical performance parameters
Efficiency
> 85 % .
Input Protection
Phase loss detection. Equipped with a dedicated 3 phases circuit breaker.
Power factor
> 85%.
AC power input connections
Harting type Han B Base Panel 2 Levers.
Power Functions and Performance
Parallel operation. The HVPS can be paralleled with a second (third) HVPS to provide twice (triple)output power. Input power may be parallel and HV output power may be parallel. Interlocks for each unit displayed on the input panel.
Regulation
40% to 100% scale of rate output, ±0.1% peak to peak (6V total voltage range at 3kV) for 0-600Hz as measured on the first consecutive pulse after a change in output voltage or rep rate.
Stability
<±0.1% within every 8 hours after 1 hour warm-up.
Linearity of programmed output voltage
40% to 100% scale of rate output,±1.0%.
Programming accuracy of output voltage
40% to100% scale of rate output, ±0.1% peak to peak (6V total voltage range at 3kV) for 0-600Hz measured on the first consecutive pulse after a change in output voltage or rep rate.
Autoinhibit
Adjustable self-rejection range from 10μs to1010μsfactory set self-rejection 500μs.
External Inhibit
The power supply allows external signals to control the output of the power supply for suppression. The high voltage is triggered by the light enable on the optical receiver, and the maximum external suppression time is 1010µs.
Status Indicators
Green LED for mains on,green LED for HV on. 5 red Leds for interlocks phase loss, Overtemp, Overvoltage, Short circuit, Remote Error. The corresponding LED will remain lit until the system is manually reset or until the fault condition is resolved.
MTBF
18000 hours minimum. To be ensured by appropriate burn-in/ measurements with a load comparable to final application. Prototype burn-in time
Load capacitance
21µF.
Charging time for a single cycle
1ms.
Charging repetition rate
0.1Hz ~ 600hz . Indefinite pause before capacitor discharge is possible. Power supply will keep HV within regulation range.
Charging repetition accuracy
±0.1%.
Load Reversal
Power supply and load will be separated by a magnetic isolator MI. Power supply is able to work with a starting voltage of about 1kV and endure voltage
reversal 10V.
End of charging signal
EOC signal will be set, when output voltage has reached set level within regulation band.
Load leakage current
Load leakage current caused by pulser< 10mA at 3kV.
Cooling
Water cooling.
Water fittings
On the housing the lower connector has to be labelled “water in”, the upper connector “water out”.
Environmental
Operating
15℃ to 50℃.
Storage
0℃ to 85℃.
Humidity
10% to 95%RH, non-condensing.
Dimensions
L520mm,W270mm,H600mm.
Weight
About 50kg.
HV output connector type
Fisher connector. 5m long HV cable.