TD2312 DC HV Power Supply

TD2312

Teslaman TD2312 series is a high-performance 19-inch standard rack-mount high-voltage power supply, capable of delivering up to 100 kV at 1 kW. Positive/negative voltage is selectable, and both output voltage and current are continuously adjustable. The high-voltage output can achieve a linear and smooth rise. The TD2312 series also supports an external potentiometer for remote control of output voltage and current, and features external voltage and current monitoring, overvoltage and short-circuit protection at the high-voltage output, arc protection, safety interlock, and other functions.

Typical Application:Ion implantation, Hi-POT testing, electrostatic electret charging, withstand voltage testing, electrical explosion, electrospinning, high-voltage power extraction, high-voltage capacitor charging, scientific research, and AI visual recognition.

Reference Back to list

Features

  • Output voltage: 1 kV~100 kV
  • Output power: 500 W~1 kW
  • Overvoltage
  • overcurrent
  • short-circuit and arc protection
  • Voltage and current adjustment function
  • Remote voltage and current adjustment 
  • Digital communication (optional) 
  • Safety interlock function
  • Supports up to 18 units in parallel

CONTACT US

Address:16 Renxian Street, High-tech Industrial Zone, Dalian, China
Mobile:+8615642371743
Wechat:15642371743
Email:yuhang@teslamanhv.com
URL:www.teslamanhv.com
DaLian Teslaman XingQiCheng

Product Specifications


Input

AC220V±10%,50Hz,7A.

Output

Rated voltage selectable from 1 kV to 100 kV; maximum output power 1 kW. Continuously adjustable from 0 to maximum voltage. Single polarity (positive or negative).

Voltage Control

Internal

Built-in encoder sets output voltage from 0 to maximum.

External remote

External 0–10 V control signal adjusts output from 0 to maximum output voltage.

Current Control

Internal

Built-in encoder sets current from 0 to maximum.

External remote

External 0–10 V control signal sets current from 0 to maximum current.

Voltage Regulation

Load

0.01% (no load to rated load).

Line

±0.01% (for ±10% input voltage change).

Current Regulation

Load

0.01% (no load to rated load).

Line

±0.01% (for ±10% input voltage change).

Ripple

Under rated output voltage, ripple voltage is 0.1% p-p of maximum output voltage.

Ambient Temperature

Operating

0 °C to +50 °C.

Storage

–20 °C to +80 °C.

Temperature Coefficient

0.01% per °C.

Stability

Less than 0.1% per 8 hours after 0.5-hour warm-up.

Voltage and Current Indication

0 to +10 V; accuracy 1% under rated output conditions.

Dimensions

W 482 mm × H 133.5 mm × D 620 mm.

Connector

High-voltage output connector

recessed epoxy resin insulating conduit and inserted high-voltage cable connected via a 16 mm diameter metal connector. Standard high-voltage cable total length

Input/Output Connector

25-pin terminal block, including control and display signals.

Remote Control of Output Voltage and Current

External potentiometer can be connected, using the internal 10 V reference voltage, for remote control of output voltage and current.

Remote Voltage and Current Indication

The 25-pin terminal block includes 0–10 V voltage and current indication signals, allowing connection to various digital or analog meters.

Download