TD2312
Teslaman TD2312 series is a high-performance 19-inch standard rack-mount high-voltage power supply, capable of delivering up to 100 kV at 1 kW. Positive/negative voltage is selectable, and both output voltage and current are continuously adjustable. The high-voltage output can achieve a linear and smooth rise. The TD2312 series also supports an external potentiometer for remote control of output voltage and current, and features external voltage and current monitoring, overvoltage and short-circuit protection at the high-voltage output, arc protection, safety interlock, and other functions.
Typical Application:Ion implantation, Hi-POT testing, electrostatic electret charging, withstand voltage testing, electrical explosion, electrospinning, high-voltage power extraction, high-voltage capacitor charging, scientific research, and AI visual recognition.
Reference Back to listFeatures
- Output voltage: 1 kV~100 kV
- Output power: 500 W~1 kW
- Overvoltage
- overcurrent
- short-circuit and arc protection
- Voltage and current adjustment function
- Remote voltage and current adjustment
- Digital communication (optional)
- Safety interlock function
- Supports up to 18 units in parallel
CONTACT US
Mobile:+8615642371743
Wechat:15642371743
Email:yuhang@teslamanhv.com
URL:www.teslamanhv.com
Product Specifications
Input
AC220V±10%,50Hz,7A.
Output
Rated voltage selectable from 1 kV to 100 kV; maximum output power 1 kW. Continuously adjustable from 0 to maximum voltage. Single polarity (positive or negative).
Voltage Control
Internal
Built-in encoder sets output voltage from 0 to maximum.
External remote
External 0–10 V control signal adjusts output from 0 to maximum output voltage.
Current Control
Internal
Built-in encoder sets current from 0 to maximum.
External remote
External 0–10 V control signal sets current from 0 to maximum current.
Voltage Regulation
Load
0.01% (no load to rated load).
Line
±0.01% (for ±10% input voltage change).
Current Regulation
Load
0.01% (no load to rated load).
Line
±0.01% (for ±10% input voltage change).
Ripple
Under rated output voltage, ripple voltage is 0.1% p-p of maximum output voltage.
Ambient Temperature
Operating
0 °C to +50 °C.
Storage
–20 °C to +80 °C.
Temperature Coefficient
0.01% per °C.
Stability
Less than 0.1% per 8 hours after 0.5-hour warm-up.
Voltage and Current Indication
0 to +10 V; accuracy 1% under rated output conditions.
Dimensions
W 482 mm × H 133.5 mm × D 620 mm.
Connector
High-voltage output connector
recessed epoxy resin insulating conduit and inserted high-voltage cable connected via a 16 mm diameter metal connector. Standard high-voltage cable total length
Input/Output Connector
25-pin terminal block, including control and display signals.
Remote Control of Output Voltage and Current
External potentiometer can be connected, using the internal 10 V reference voltage, for remote control of output voltage and current.
Remote Voltage and Current Indication
The 25-pin terminal block includes 0–10 V voltage and current indication signals, allowing connection to various digital or analog meters.