TCM6006 DC HV Power Supply

TCM6006

Teslaman TCM6006 series high voltage power supply, using full digital PID control mode, over-voltage and over-current short circuit protection, fast voltage and current transient response capability, up to 0.01% stable output. 

Typical Application:Electrostatic electret, Electrostatic wire separation, Electrostatic separation, Electrostatic elimination, Electrostatic spinning, Electrostatic printing and other electrostatic applications.

 

Reference Back to list

Features

  • Maximum Output Voltage 50kV
  • Adjustable
  • Maximum Output Current 1mA
  • Maximum Output Power 50W
  • Abnormal Full Protection
  • RS-485 Digital Communication Interface

CONTACT US

Address:16 Renxian Street, High-tech Industrial Zone, Dalian, China
Telephone:+86411-84754722
Mobile:+8615642371743
Wechat:15642371743
Email:chengxingqi@teslamanhv.com
URL:www.teslamanhv.com
DaLian Teslaman XingQiCheng

Product Specifications


Input

AC220V ± 10%, 50/60 Hz.

Output

The maximum voltage is 50kV, the maximum output current is 1mA, and the maximum power is 50W.

Front Panel Functions

power on/off, whether self-start, whether memory, voltage/current preset, high voltage output/turn-off, user interface settings and voltage output adjustment.

Front Panel Status Indication

polarity indication, constant voltage/constant current mode, self-starting status, memory status, preset status, output status and abnormal code display.

Voltage Control

The rotary encoder of the power supply can set the output voltage between 0 and the highest voltage.

Current Control

Current regulation can be realized through preset functions.

Coarse/Fine Adjustment Function

The power supply automatically identifies coarse/fine adjustment according to the rotation rate of the knob. Large step output when rotating quickly and small step output when rotating slowly.

Remote Control

RS-485 digital communication interface can be optional, and can communicate with the host computer or other digital equipment. Our company provides upper computer software for testing only. The equipment adopts Modbus communication protocol, and refer to Appendix "Communication Protocol Part" for relevant information.

Voltage Regulation Rate

Load

0.01% of output voltage no load to full load.

Line

  0.01% for  10% change in input voltage.

Current Regulation Rate

Load

0.01% of output current from 0 to rated voltage.

Line

   0.01% for  10% change in input voltage.

Ripple Voltage

It is less than 1% Vrms at rated voltage (0.1% Vp-p is optional).

Environmental

Operational

0 ℃ to 50 ℃. Storage

Temperature Coefficient

Usually 100ppm per ℃.

Stability

It is less than 0.1% every 8 hours after 1/2 hour warm up.

Humidity

10-90% without condensation.

Voltage and Current Display

Three-digit nixie tube, voltage accuracy ± (0.5% +1), current accuracy ± (4% +3).

Overall Dimensions

The width is 214mm, the height is 67mm and the depth is 285mm.

Weight

About 4.8 kg.

High Voltage Output Line

The power supply has its own shielded high-voltage cable. The standard high voltage cable is 2 meters long and 5.5 mm outside diameter. Other lengths are optional. 