Neutron Accelerator High-Voltage Supplies in Nuclear Safety Material Testing

Neutron-based inspection methods play an important role in the verification of materials used in nuclear facilities and in the characterization of components that must withstand radiation environments. Neutron radiography, neutron diffraction and neutron activation analysis provide information that complements the X-ray techniques, particularly for the detection of light elements and the measurement of residual stress and crystalline structure. The compact neutron generators that serve these applications accelerate deuterium or tritium ions onto a target, producing neutrons through fusion reactions, and the accelerator is powered by a high-voltage supply that must operate reliably in the demanding environment of the testing facility. The performance of the high-voltage supply determines the neutron output stability, the operating duty cycle and the safety of the facility. 

The neutron output of the accelerator is a strong function of the accelerating voltage. The fusion cross-section rises steeply with the ion energy in the operating range of the compact generators, and a small change in the accelerating voltage produces a proportionally larger change in the neutron yield. The high-voltage supply must therefore maintain the accelerating voltage with high stability, and the regulation must hold during the pulsed operation that many testing protocols require. The pulse-to-pulse reproducibility of the neutron output is essential for the quantitative analysis techniques, and the statistical variations of the output must remain within the limits that the measurement uncertainty budget allows. 
The architecture of the generator supply follows the requirements of the ion source and the accelerating column. The ion source is supplied through a separate power channel that controls the discharge current and the gas flow, and the extracted ion beam is accelerated by the high voltage applied across the accelerating column. The interaction between the ion source parameters and the accelerating voltage determines the beam current and the neutron yield, and the control system coordinates the two channels to maintain the target beam conditions. The supply includes the beam current measurement and the protection functions that respond to the beam interception and the vacuum faults. 
The insulation of the accelerating column and the high-voltage components is a critical design area. The accelerating voltage in the range of tens to hundreds of kilovolts is applied across the column, and the insulation must withstand the operating voltage with the margin required by the safety standards. The high-voltage section is typically enclosed in a gas-insulated or oil-insulated housing, and the dielectric properties of the insulation medium must be verified at the operating conditions. The temperature of the insulation affects the breakdown margin, and the cooling of the high-voltage section is part of the system design. 
The radiation environment of the neutron facility affects the electronic components of the supply. The neutron and gamma fields cause the degradation of the semiconductor devices and the drift of the sensitive components, and the control electronics are located as far from the source as practical, with the signals transferred through fiber-optic links that are immune to the radiation effects. The components that must operate near the source are selected for the radiation tolerance, and the qualification of the components includes the irradiation testing at the expected dose levels. The failure of an electronic component in the radiation environment has different characteristics than a failure in a benign environment, and the diagnostic strategy accounts for the radiation-induced failure modes. 
The safety systems of the neutron facility extend to the high-voltage supply. The radiation protection interlocks, the personnel access controls and the radiation monitoring are integrated with the high-voltage enable chain, so that the high voltage cannot be applied when the facility conditions are not safe. The supply implements the redundant safety paths that remove the high voltage through hardware circuits independent of the software, and the safety verification includes the fault injection testing of each path. The residual charge of the high-voltage system is discharged through the controlled bleed circuits after the shutdown, and the discharge state is indicated to the operators. 
The reliability of the supply under the continuous and cyclic operation determines the productivity of the testing facility. The generators operate in alternating periods of beam-on and beam-off, and the thermal cycling of the high-voltage components and the switching devices accumulates over the operating life. The design uses the components with proven long-life characteristics and the derating that accounts for the cyclic loads, and the monitoring of the temperatures and the electrical parameters supports the condition-based maintenance. The maintenance of the ion source and the target, which are the consumable elements of the generator, is coordinated with the inspection of the high-voltage system. 
The data acquisition of the testing facility integrates the neutron measurement data with the generator operating parameters. The correlation of the neutron output with the accelerating voltage, the beam current and the gas pressure provides the calibration of the generator performance and the early detection of the degradation. The automatic logging of the operating data supports the traceability of the test results, which is required for the qualification of the materials and the components. The remote monitoring of the generator status enables the expert support from the equipment manufacturer, reducing the downtime of the facility. 
The development of the compact neutron generators for the material testing applications continues to advance the high-voltage technology.
The qualification of the high-voltage supply for the nuclear material testing service involves the verification of the electrical performance and the safety functions under the conditions representative of the facility operation. The type tests include the voltage stability measurements over the specified temperature range, the pulsed operation tests at the full repetition rate and the fault handling tests that simulate the abnormal conditions. The acceptance testing of the individual units verifies the conformity of each unit with the type test results, and the test records form part of the equipment documentation. The periodic verification during the service life maintains the validity of the qualification and supports the continued operation of the facility. The trend toward higher neutron output, longer continuous operation and improved pulse control places increasing demands on the accelerating supplies. The integration of the digital control, the advanced protection and the data connectivity transforms the high-voltage supply from a passive power source into an intelligent component of the testing system, and the reliability and the stability of the supply remain the foundation of the neutron-based material characterization.