Control of High-Voltage Supplies for Excimer Laser Light Sources in High-Numerical-Aperture Immersion Lithography Systems

  Excimer laser light sources in immersion lithography operate at pulse repetition rates in the kilohertz range, with energy stability requirements measured in fractions of a percent. The high-voltage supply that drives the discharge chamber sits at the head of a control chain whose settling behaviour determines both dose accuracy and the lifetime of the chamber optics.

  A discharge-pumped laser requires a pulse-forming network charged to a precise potential before each discharge. The supply charges the network between pulses, and the charging interval, typically a few hundred microseconds, bounds the achievable repetition rate. Charging speed and charging precision trade against each other, and the operating point is chosen to balance throughput against dose stability.
  Charging precision translates directly into pulse energy stability. A potential error of one part in a thousand produces an energy error of roughly two parts in a thousand, because the deposited energy scales with the square of the charging potential. Dose control in immersion systems requires energy stability better than one part in a thousand, which fixes the supply stability requirement at the sub-percent level.
  Energy correction between pulses provides the margin. A metering system measures each pulse and the controller adjusts the charging potential for the next pulse, compensating slow drift and pulse-to-pulse variation. The correction loop bandwidth is limited by the repetition rate, and the loop must be stable against the discrete sampling that the pulse train imposes.
  Chamber ageing changes the relationship between potential and energy. Electrode erosion and gas degradation alter the discharge impedance, and the energy produced for a given charging potential declines over the campaign. A fixed potential-to-energy mapping becomes inaccurate, and the correction loop absorbs the change until the loop authority is exhausted.
  Maintaining loop authority requires periodic recalibration. Adjusting the mapping at gas-change intervals restores the authority and keeps the correction loop operating in the middle of the range. Skipping the recalibration shortens the useful life of the gas fill and increases the rate of dose errors.
  Magnetic pulse compression stages sit between the supply and the chamber, and the behaviour of those stages influences the charging waveform. Saturable reactors present a load that changes during the pulse, and the supply must tolerate the reflected waveform without protection trips. Matching the supply output impedance to the compression network reduces the reflection and improves charging efficiency.
  Timing stability is as important as magnitude stability. The charging interval must end at a defined instant before the discharge trigger, and jitter in the charging completion shifts the discharge conditions. A charging supply with variable completion time, caused by load variation, produces energy jitter that the correction loop cannot remove because the measurement arrives after the pulse.
  Grounding and shielding determine whether the measured stability survives installation. The discharge produces broadband emissions that couple into the metering electronics, and the resulting measurement noise appears as false energy variation. Shielding the metering path, and referencing the measurement to the chamber ground rather than to the cabinet ground, removes the artefact.
  Thermal management of the supply affects long-term stability. Charging capacitors self-heat during high-repetition operation, and the capacitance changes with temperature. Compensation through a temperature-dependent charging model keeps the delivered charge constant, and the model is calibrated during commissioning.
  Immersion-specific constraints add a layer. The projection optics operate in a controlled environment where vibration and thermal gradients are tightly managed, and the supply must not introduce either. Water cooling with low flow noise, and mounting that isolates vibration, are prerequisites rather than refinements.
  Service practice in this application emphasises condition data over calendar schedules. Charging efficiency, capacitor temperature, pulse energy trend and correction-loop authority together indicate the remaining margin, and maintenance is scheduled when the margin falls rather than when the hours expire.
  Designers report a consistent finding: the supply meets specification on the bench long before the installation is stable in production. The gap between bench and production is closed by grounding, shielding and recalibration discipline rather than by further refinement of the converter.