High-Voltage Mass Spectrometer Supplies in Clinical Toxicology Analysis

Clinical toxicology laboratories identify and quantify drugs, metabolites and poisons in biological samples, and the results guide emergency treatment, therapeutic drug monitoring and forensic decisions. Mass spectrometry, in the various hyphenated forms, has become the analytical method of choice for these applications because of the specificity and the sensitivity that the technique offers. The mass spectrometer depends on a network of high-voltage supplies that generate the ionization potentials, the accelerating fields and the detector biases, and the performance of these supplies directly affects the accuracy, the precision and the reliability of the toxicology results. The requirements of the clinical environment, including the high sample throughput, the strict quality control and the need for minimal operator intervention, shape the design of the high-voltage systems. 

The ionization interface of a modern mass spectrometer operates at high voltage in several configurations. In electrospray ionization the sample solution is sprayed from a capillary held at a potential of several kilovolts relative to the inlet, and the stability of this potential determines the ionization efficiency and the stability of the ion signal. In atmospheric pressure chemical ionization the corona discharge that ionizes the analyte is sustained by a high-voltage needle, and the discharge current is regulated to maintain a constant ionization rate. The high-voltage supplies for these interfaces must provide a stable, low-noise output with a fast response to the changes in the solvent composition and the flow rate that occur during the chromatographic run. 
The mass analyzer section imposes the most stringent stability requirements. In quadrupole analyzers the mass-to-charge selection is performed by a combination of a radio-frequency voltage and a DC voltage, and the mass calibration depends on the accuracy and the stability of both voltages. In time-of-flight analyzers the ions are accelerated by a pulsed high voltage, and the flight time, and hence the mass resolution, depends on the reproducibility of the acceleration pulse. The supplies for the analyzer section must maintain the voltage stability over the duration of the analytical run and across the operating temperature range, and the drift of the voltages is corrected through the periodic mass calibration that the quality system requires. 
The detector section of the mass spectrometer converts the ion current into a measurable signal, and the gain of the detector is set by the high voltage applied across the multiplying structure. The electron multiplier and the microchannel plate operate at potentials of several kilovolts, and the gain varies steeply with the applied voltage. A small drift in the detector voltage produces a measurable change in the signal intensity, which would bias the quantitative results. The detector supply must therefore provide a highly stable output, and the response of the detector gain to the voltage must be characterized and monitored through the internal calibration procedures. 
The clinical toxicology laboratory processes a large number of samples, and the stability of the mass spectrometer over long analytical sequences is essential. The high-voltage supplies operate continuously for extended periods, and the thermal drift of the components must be compensated through the design or through the control algorithms. The instrument performs automatic checks at defined intervals, including the mass calibration and the response verification, and the results of these checks detect the onset of the supply drift before the drift affects the patient results. The data from the checks is logged, and the trend analysis of the check results provides an early warning of the component aging. 
The safety of the operators and the reliability of the instrument in a routine laboratory environment are important design considerations. The high-voltage sections are enclosed and interlocked, and the discharge of the stored energy after the power-down is performed through a controlled bleed circuit. The service procedures, including the replacement of the detector and the cleaning of the ion source, require the safe discharge of the high-voltage components, and the design provides the discharge indicators and the lockout mechanisms that support the service operations. The failure of a high-voltage component is detected by the instrument diagnostics, and the fault messages guide the service engineer to the affected module. 
The accuracy of the toxicology results depends on the calibration of the entire analytical system, including the high-voltage parameters. The mass calibration establishes the relationship between the analyzer voltages and the mass scale, and the response calibration establishes the relationship between the signal intensity and the analyte concentration. The calibration procedures are performed with certified reference materials, and the calibration records are maintained to meet the requirements of the laboratory accreditation. The high-voltage supplies support the calibration by providing the stable and reproducible voltage settings that the calibration process requires. 
The throughput of the clinical laboratory is driven by the sample volume and the turnaround time requirements. The mass spectrometer operates in a continuous sequence of injections, and the downtime of the instrument has a direct impact on the laboratory capacity. The reliability of the high-voltage systems is therefore a key factor in the operational efficiency, and the preventive maintenance program includes the periodic inspection of the high-voltage components, the replacement of the consumable parts and the verification of the electrical parameters. The instrument manufacturers provide the maintenance schedules and the diagnostic tools that support the efficient servicing of the systems. 
The evolution of the clinical mass spectrometry applications, including the expansion of the therapeutic drug monitoring and the newborn screening programs, increases the demands on the instrument performance. The high-voltage supplies must support the higher sensitivity, the faster scan speeds and the wider mass ranges that the new applications require. The integration of the high-voltage control into the instrument software enables the automated optimization of the parameters and the simplified operation of the systems. The continued development of the high-voltage technology in the mass spectrometer remains an important driver of the clinical diagnostic capability.
Quality control in the toxicology laboratory places additional demands on the stability of the analytical system. The control samples that accompany each batch are used to verify the accuracy and the precision of the measurements, and the acceptance criteria for the control results are defined by the laboratory quality procedures. A drift in the high-voltage parameters that occurs between the calibration runs is detected through the control results, and the investigation of the out-of-specification results includes the review of the instrument performance data. The linkage between the electrical parameters of the mass spectrometer and the analytical quality metrics provides the basis for the continuous monitoring of the instrument health. The systematic recording of the instrument state at the time of each measurement supports the retrospective review of the results and the identification of the systematic errors.