蚀刻设备高压电源对等离子体鞘层厚度动态调控的功率匹配技术

  A plasma etch chamber is a load whose impedance changes with the process, and the radio frequency power that sustains the plasma must be delivered into that changing impedance. The high voltage supply in this context is usually the bias supply that controls the sheath, and the sheath thickness sets the ion energy at the wafer, which in turn sets the anisotropy of the etch. Controlling the sheath therefore means controlling the ion energy distribution, and the distribution is what distinguishes a vertical wall from an undercut.

  The sheath behaves as a capacitor whose thickness depends on the plasma density and on the applied bias. When the bias rises, the sheath thickens and the ion energy rises, but the thickening also reduces the effective capacitance, which changes the impedance seen by the bias supply. A supply that is matched at one bias point will be mismatched at another, and the mismatch shows up as reflected power that heats the matching network instead of the wafer.
  The standard solution is a match network that tunes the load to the source, but the tuning must follow the sheath dynamics rather than the average impedance. A mechanical match with a time constant of a second cannot follow a bias step, so the reflected power spikes during the step and the plasma is perturbed. An electronic match with a response in the microsecond range follows the step and keeps the reflected power low, and the difference is visible in the etch profile at the start of each step.
  Pulsed bias is the other technique that has become common. The bias is switched on and off at a duty cycle, and the off period allows the wafer to discharge, which reduces charge accumulation and narrows the ion energy distribution. The supply must deliver a short bias pulse with a defined amplitude and a fast edge, and the match network must remain tuned during the off period so the next pulse starts into a matched load. A network that detunes during the off period produces a reflected power spike at each pulse, and the spike erodes the electrodes.
  The high voltage supply design follows from these requirements. The output stage must deliver a defined voltage with a rise time of a few microseconds and a fall time that can be programmed, because the fall time controls the low energy tail of the distribution. A push-pull stage with an active discharge path gives a programmable fall, whereas a resistive discharge gives a fixed one that is too slow for narrow distributions.
  Measurement is difficult because the voltage and current at the wafer are not accessible. A voltage probe at the electrode and a current probe in the feed line give the impedance at the electrode, and a model of the sheath converts the electrode measurement to the wafer. The model needs the plasma density, which is measured by a separate diagnostic, and the conversion must be validated against a wafer-based measurement at intervals. Validating once and then trusting the model for months is how errors accumulate unnoticed.
  Arcing is the dominant failure mode in an etch chamber, and the arc energy that reaches the wafer determines the damage. A supply that limits the arc current within a microsecond and then removes the energy within a few milliseconds limits the damage to a level that the subsequent process can tolerate. The current limit must be set above the normal operating current with enough margin that a transient from the plasma does not trip the limit, and the margin is determined by the largest transient expected, which is usually the ignition of the plasma.
  Records that capture the bias waveform, the reflected power and the arc events for each wafer give a data set that can be correlated with the etch results. When a lot shows a systematic profile shift, the correlation points to the parameter that moved, and the repair is then targeted rather than experimental.
  The power matching problem extends beyond the bias supply to the source power that sustains the plasma. Source power sets the density, bias power sets the energy, and the two interact: raising the source power raises the density, which thickens the sheath for a fixed bias and lowers the ion energy. A recipe that changes source power to adjust uniformity must therefore adjust bias power to keep the energy, and the adjustment is a calibration curve rather than a constant.
  Frequency choice matters for matching. A bias at a high frequency couples through the sheath more efficiently, so less voltage is needed for the same energy, which reduces the sputtering of the chamber walls. A bias at a low frequency gives a wider energy distribution, which is sometimes desirable for trench bottom coverage. Dual frequency supplies allow the distribution to be shaped, and the shaping requires the two frequencies to be synchronised, because an unsynchronised pair produces a beating distribution that changes with the phase.
  Wafer temperature interacts with the bias. Ion bombardment heats the wafer, and the heat changes the resist chemistry and the etch rate. The chuck cools the wafer with helium backside conduction, and the conduction depends on the contact pressure, which depends on the clamp. A bias supply that delivers a stable energy still produces a varying wafer temperature if the clamp pressure varies, so the temperature must be measured and the clamp regulated rather than assumed.
  Diagnostics for an etch chamber should include the bias waveform as delivered, the reflected power, the chamber pressure and the wafer temperature. The four together explain most profile problems. A profile that tilts usually correlates with a reflected power asymmetry, a profile that undercuts usually correlates with a high wafer temperature, and a profile with a notch at the bottom usually correlates with an energy distribution that has a low energy tail from a slow fall time.
  Power matching in a production etch tool is ultimately judged by the reflected power trend rather than by a single measurement, because the trend shows the direction in which the chamber is drifting. A reflected power that creeps upward over a hundred wafers indicates a wall condition change, a target condition change on the source side, or a match element that is wearing; the three are separated by checking the source reflected power at the same time, which usually stays flat when the bias side is at fault.
  The matching hardware and the bias supply should therefore be treated as one subsystem during commissioning, with a joint test that sweeps the bias amplitude across the recipe range and records the reflected power at each step. A joint test reveals interaction that separate tests hide, and the interaction is what produces the profile defects that a recipe change cannot fix.
  A chamber whose reflected power is flat across the recipe range is a chamber whose bias supply and match network have been commissioned as a subsystem, and that is the state in which the process reproduces from wafer to wafer without recipe drift.
  Wafer-level charging, wall condition and pulse shape are the three variables that a bias supply and its match network must hold together, and a tool that holds them produces the same profile on the first wafer of a lot as on the last.
  The joint test also documents the interaction, and documentation of interaction is what allows a recipe to be transferred to a second chamber without repeating the whole development.
  Matching networks for pulsed bias must be designed with the off period in mind. During the off period the plasma is still present, so the load impedance is not an open circuit; it is a low loss capacitance. A network that is tuned for the on state is therefore detuned in the off state by an amount that depends on the sheath collapse. Networks that use a fixed element with a wide bandwidth tolerate the detuning better than narrowband networks, and the cost is a small loss of efficiency in the on state, which is usually acceptable given the reduction in reflected power spikes.
  Chamber wall condition affects the bias behaviour through the sheath capacitance. A wall that has been coated by a previous process changes the effective area of the return electrode, which changes the sheath capacitance and therefore the matching. Cleaning the chamber restores the original condition, and recording the reflected power after each clean gives an indication of how far the walls have drifted. Scheduling the clean on the reflected power trend rather than on a fixed interval keeps the process stable while avoiding unnecessary downtime.
  Wafer-level charging is reduced by pulsing but not eliminated. During the on period the wafer still accumulates charge, and if the pulse is long the charge can deflect the incoming ions and produce a tilt in the sidewall. A short pulse with a high amplitude delivers the same average energy with less charge accumulation, and the supply's ability to deliver a short pulse with a defined shape is what makes that option available. Specifying the pulse shape, rather than only the amplitude, is therefore the relevant requirement for a modern etch tool.