Thermal Management Technology for Instantaneous High-Power Pulse Release of High Voltage Power Supplies in Counter-Swarm Drone Directed Energy Weapons

Pulsed high power supplies are specified by peak power in the pulse and by average power over a burst, and the two numbers lead to different thermal designs. The peak sets the switch rating and the stored energy; the average sets the heat sink and the cooling. A design that meets the peak with a marginal average survives a single pulse and fails during a burst, and the failure is thermal rather than electrical.

The energy that a pulse deposits in the switches is the integral of the current and the voltage over the switching transition, and at high peak currents the transition is longer than the datasheet suggests because the gate drive cannot charge the gate fast enough at high drain voltage. The result is a per pulse loss that is a few times the calculated value, and the discrepancy shows up as a junction temperature that rises faster than the model predicted.
Thermal impedance in pulse duty is not the steady state value. The junction to case impedance falls with pulse width and rises with duty, and a datasheet that gives one number for a ten millisecond pulse says nothing about a hundred microsecond pulse at a repetition rate of a few kilohertz. The relevant curve is the transient thermal impedance, and the curve has to be read at the actual pulse width.
Heat spreading in the package is the first bottleneck. A die that is a few millimetres across deposits the pulse energy in a volume that is smaller than the heat spreader, and the spreading resistance dominates the first hundred microseconds. A package with a thicker copper layer spreads the heat faster and lowers the peak junction temperature, and the improvement is visible in the derating curve rather than in the headline current rating.
Cooling design for burst operation has to account for the thermal mass of the heat sink. A sink that is sized for the average power reaches a steady temperature over minutes, and a burst that lasts seconds is absorbed by the sink's mass before the fan has done any work. Sizing the sink for the burst energy rather than for the average power is the difference between a design that survives a burst and one that rides the protection.
Phase change materials are useful in a narrow window. A material that melts at a temperature just below the junction limit absorbs a burst's energy at a nearly constant temperature and releases the energy to the sink between bursts. The window is narrow because the material has to re-solidify between bursts, and a repetition rate that is faster than the re-solidification time makes the material useless.
Paralleling devices for peak current brings a thermal sharing problem. Two devices in parallel share the current according to on state resistance and threshold voltage, and the device that carries more current runs hotter, which lowers the threshold further and increases the share. A small emitter resistance or a separate gate resistor slows the positive feedback and keeps the sharing within a few percent, and the resistor costs a fraction of a percent of efficiency.
Thermal cycling is the long term failure mechanism in pulsed service. Every pulse produces a temperature swing at the die attach and the wire bonds, and the swing accumulates into fatigue. A swing of twenty degrees at a repetition rate of a few kilohertz produces millions of cycles in a day, and the die attach that survives a thousand cycles can fail at ten million. The design response is to reduce the swing rather than to hope the attach is good.
Monitoring junction temperature in service is possible without a dedicated sensor. The forward voltage of a diode or the on state resistance of a switch carries a temperature coefficient, and the coefficient can be measured during a calibration pulse and used afterwards. The measurement is crude and adequate for a protection that derates the repetition rate when the temperature approaches the limit.
Capacitor banks in a pulsed supply are a thermal component as well. The bank stores the pulse energy and carries a ripple current that heats the dielectric, and the heating is concentrated in the middle of the bank where the cooling is worst. Spacing the capacitors for airflow, and measuring the case temperature of the hottest unit rather than the average, catches the hot spot before a can vents.
The busbar that connects the bank to the switches carries the pulse current, and the losses in the bar are resistive and concentrated at the joints. A joint that is a few milliohms produces a voltage drop that is small at average current and significant at peak current, and the drop appears as an unexplained reduction of output during the pulse. Torqued joints with a specified value, checked at every reassembly, keep the drop predictable.
Protection thresholds have to be set with the thermal time constants in mind. A current threshold that responds in a microsecond protects the switches from a fault and also trips on the normal pulse if the pulse current is close to the threshold. A two level protection, with a fast trip at a high level and a slower trip at a level just above the normal pulse, separates the fault from the process.
Derating curves for pulsed service should be measured rather than extrapolated. The measurement requires a fixture that can run the actual pulse shape at the actual repetition rate for hours, and the fixture is more expensive than the supply. Building the fixture once and reusing the data across designs is the practical arrangement, and the data becomes the reference for every later thermal decision.
The thermal design of a pulsed supply ends with a test that runs the full burst profile to thermal equilibrium. Equilibrium is reached when the junction temperature stops rising between bursts, and the time to reach equilibrium is often an hour. A test that stops after ten minutes reports a temperature that is twenty degrees below the real one, and the margin calculated from that number is imaginary.
Gate drive energy is a thermal load that the power stage calculation usually omits. Each pulse charges and discharges the gate capacitance, and at a few kilohertz with a large die the drive energy is a few watts per switch. The energy lands in the driver, which is a small package with a small thermal pad, and a driver that is thermally marginal fails long before the switch does.
The temperature measurement that matters is the one at the die attach, and the accessible proxy is the case temperature with a defined thermal resistance between the two. A case thermocouple reading taken at the wrong point reports a temperature that is several degrees low, and the derating that follows is optimistic by the same amount. A small hole drilled to the case near the die, filled with a thermal compound and a fine thermocouple, gives a reading that is usable.
Thermal interfaces are the cheapest place to lose margin. A layer of thermal compound that is too thick, or a pad that has been reused, adds a resistance that is comparable with the package's own. Measured interface resistance on a production unit, rather than the datasheet value of the material, keeps the thermal model honest.
Air cooling at high altitude loses effectiveness in a way that is easy to forget. The mass flow falls with density, and a design validated at sea level runs hotter at altitude for the same fan and the same sink. A derating table indexed by altitude, rather than by ambient temperature alone, is the practical answer for equipment that travels.
Liquid cooling brings a different failure mode. A cold plate that is partially blocked by corrosion products cools well at the inlet and poorly at the outlet, and the outlet device fails first. Flow measurement with a differential pressure switch, and a maintenance interval based on the water quality rather than on hours, keep the block from becoming the failure.
Burst mode operation creates a thermal staircase that the steady state model does not capture. Each burst raises the sink temperature by a step, and the steps accumulate over a shift until the sink reaches equilibrium. A design that is validated over one burst has validated the staircase's first step only, and the equilibrium temperature can be twenty degrees higher.
Records of thermal behaviour over a service interval show whether the cooling path is degrading. The same load at the same ambient producing a higher case temperature after six months is a sign of a blocked fin, a dried compound, or a fan that has lost speed. Trend data of this kind is more useful than a single pass or fail result.
Thermal design for pulse service is mostly a matter of measuring the right quantity at the right moment, and the right moment is thermal equilibrium rather than the end of the first burst.
A pulsed design that is validated at thermal equilibrium is a design whose margin is a measured number rather than an assumption.
Peak power is cheap to quote and expensive to cool. The heatsink sees the average, the junction sees the peak.